-
NSGA2-matlaB
NSGA2,MATLBD代码 Non-dominated Sorting Genetic Algorithm II (NSGA-II)
- 2020-11-30下载
- 积分:1
-
AMCap源代码,DirectShow
AMCap源码,使用VS2012和VS2015编译通过。可以参考博客http://blog.csdn.net/buynow123/article/details/49965493
- 2020-12-06下载
- 积分:1
-
平面变压器3D仿真资料
采用COMSOL软件,对平面变压器的仿真过程进行叙述,让大家了解平面变压器的仿真流程,是个很好的指导教材Solved with COMSOL Multiphysics 5.0Results and discussionThe magnetostatic analysis yields an inductance of 0. 1l mH and a dc resistance of0. 29 mQ2. Figure 2 shows the magnetic flux density norm and the electric potentialdistributionvolume: Coil potentiaL()Volume: Magnetic flux density norm (t▲0.07▲2.88×10-42.51.50.03050.01V656×107v0igure 2: Magnetic flux density norm and electric potential distribution for themagnetostatic analysisIn the static (DC) limit, the potential drop along the winding is purely resistive andcould in principle be computed separately and before the magnetic flux density iscomputed. When increasing the frequency, inductive effects start to limit the currentand skin effect makes it increasingly difficult to resolve the current distribution in thewinding. At sufficiently high frequency, the current is mainly flowing in a thin layernear the conductor surface. When increasing the frequency further. capacitive effectscome into play and current is flowing across the winding as displacement currentdensity. When going through the resonance frequency, the device goes from behavingas an inductor to become predominantly capacitive. At the self resonance, the resistivelosses peak due to the large internal currents Figure 4 shows the surface current3 MODELING OF A 3D INDUCTORSolved with COMSOL Multiphysics 5.0distribution atl MHz. Typical for high frequency the currents are displaced towardsthe edges of the conductor.freq(1)=1.0000E6_Surfaee: Surface-current density norm (A/)▲18618Q16010¥1.02Figure 3: Surface current density at I MHz (below the resonance frequency)Figure 4 shows how the resistive part of the coil impedance peaks at the resonancefrequency near 6MHz whereas Figure 5 shows how the reactive part of the coiimpedance changes sign and goes from inductive to capacitive when passing throughthe resonance4 MODELING OFA3DINDUCTORSolved with COMSOL Multiphysics 5.0Global: Lumped port impedance(Q2)d port impedance7.5G6.583275655545352510.10.20.30.40.509igure 4: Real part of the electric potential distribution5 MODELING OF A INDUCTORSolved with COMSOL Multiphysics 5.0Global: Lumped port impedance(Q2)35000Lumped port impedance200001000050000500010000-1500020000250000.10.20.30.40.50.60.70.809Figure 5: The reactive part of the coil impedance changes sign hen passing through theresonance frequency, going from inductive to capacitiveModel library path: ACDC_Module/Inductive_ Devices_and_coils/inductor 3dFrom the file menu. choose newNEWI In the new window click model wizardMODEL WIZARDI In the model wizard window click 3D2 In the Select physics tree, select AC/DC> Magnetic Fields(mf)3 Click Add4 Click StudyMODELING OF A3D NDUCTORSolved with COMSOL Multiphysics 5.05 In the Select study tree, select Preset Studies>StationaryGEOMETRYThe main geometry is imported from file. Air domains are typically not part of a CaDgeometry so they usually have to be added later. For convenience three additionaldomains have been defined in the CAd file. These are used to define a narrow feed gapwhere an excitation can be appliedport l(impl)I On the model toolbar, click Import2 In the Settings window for Import, locate the Import section3 Click Browse4 Browse to the models model library folder and double-click the filenductor 3d. mphbinSphere /(sphl)I On the Geometry toolbar, click Sphere2 In the Settings window for Sphere, locate the Size section3 In the Radius text field, type 0.2ick to expand the Layers section. In the table, enter the following settingsLayer nameThickness(m)ayer0.055 Click the Build All Objects buttonForm Union(fin)i On the Geometry toolbar, click Build AllClick the Zoom Extents button on the Graphics toolbar7 MODELING OF A 3D INDUCTORSolved with COMSOL Multiphysics 5.03 Click the Wireframe Rendering button on the Graphics toolbarThe geometry should now look as in the figure below0.1-0.10.20.0.0.1y0.0.2Next, define selections to be used when setting up materials and physics Start bdefining the domain group for the inductor winding and continue by adding otheruseful selectionsDEFINITIONSExplicitI On the Definitions toolbar, click Explicit2 In the Settings window for Explicit, in the Label text field, type Winding3 Select Domains 7,8 and 14 onlyI On the Definitions toolbar, click Explicit2 In the Settings window for Explicit, in the Label text field, type Gap3 Select domain 9 onlI On the Definitions toolbar, click Explicit8 MODELING OF A3DINDUCTORSolved with COMSOL Multiphysics 5.02 In the Settings window for Explicit, in the Label text field, type core3 Select Domain 6 onlyExplicit 4I On the Definitions toolbar, click Explicit2 In the Settings window for Explicit, in the Label text field, type InfiniteElements3 Select Domains 1-4 and 10-13 onlyExplicit 5I On the Definitions toolbar, click Explicit2 In the Settings window for Explicit, in the Label text field, type Non-conducting3 Select Domains 1-6 and 9-13 onlyI On the Definitions toolbar, click Explicit2 In the Settings window for Explicit, in the Label text field, type Non-conductingwithout Ie3 Select Domains 5, 6, and 9 only.Infinite Element Domain /(iel)Use infinite elements to emulate an infinite open space surrounding the inductorI On the definitions toolbar click Infinite element domain2 In the Settings window for Infinite Element Domain, locate the Domain Selectionsection3 From the Selection list. choose Infinite Elements4 Locate the Geometry section From the Type list, choose SphericalNext define the material settingsADD MATERIALI On the Model toolbar, click Add Material to open the add Material window2 Go to the Add material window3 In the tree, select AC/DC>Copper.4 Click Add to Component in the window toolbar9 MODELING OF A 3D INDUCTORSolved with COMSOL Multiphysics 5.0MATERIALSCopper(mat/)I In the Model Builder window, under Component I(comp l)>Materials click Copper(matD)2 In the Settings window for Material, locate the Geometric Entity Selection section3 From the Selection list, choose windingADD MATERIALI Go to the Add Material window2 In the tree. select built-In>Air3 Click Add to Component in the window toolbarMATERIALSAir(mat2I In the Model Builder window, under Component I(comp l)>Materials click Air(mat2)2 In the Settings window for Material, locate the Geometric Entity Selection section3 From the Selection list, choose Non-conductingThe core material is not part of the material library so it is entered as a user-definedmateriaMaterial 3(mat3)I In the Model Builder window, right-click Materials and choose Blank Material2 In the Settings window for Material, in the Label text field, type Core3 Locate the geometric Entity Selection section4 From the selection list choose Core5 Locate the Material Contents section. In the table, enter the following settingsPropertName Value Unit Property groupElectrical conductivity sigma0S/IBasicRelative permittivity epsilonrBasicRelative permeability mur1e3Basic6 On the model toolbar. click Add Material to close the Add Material windowMAGNETIC FIELDS (MF)Select Domains 1-8 and 10-14 only0MODELING OF A 3D INDUCTOR
- 2020-12-10下载
- 积分:1
-
基于stm32制作的电子体重秤源码
本人毕业设计所做,经测试可以获得体重数据并实时显示,采用hx711作为数据采集器,stm32为处理器,lcd液晶屏显示出来
- 2020-11-05下载
- 积分:1
-
黄金矿工源码
这个小程序自己写了,时间紧促,其中有不足之处,希望谅解,这个程序只是供大家学习用,开发环境是xcode cocos2d-x
- 2020-12-01下载
- 积分:1
-
PID算法实现代码,包括增量式和位置式PID代码
PID算法实现代码,包括位置式增量式数字PID实现代码。对大家编写PID程序有帮助哦。
- 2020-12-05下载
- 积分:1
-
史密斯原图,导纳图,阻抗图求解程序
【实例简介】本程序当给出任意一个点,就可求出它史密斯原图,导纳图,阻抗图的解
- 2021-11-16 00:34:17下载
- 积分:1
-
ISO 11898-3 中文
ISO 11898-3-2006道路车辆—控制器区域网络(CAN)—第三部分:低速,容错,媒体专用接口前ISO(国际标准化组织)是一个世界性的国际化标准组织(ISO成员团体)。制定国际标准的工作通常是由ISO技术委员会来完成的。何一个对已绎成立的技术委员会感兴趣的成员机构都有权派代表参加该委员会。与ISO有关的国际组织,政府和非政府国际标准化组织,也可参加有关的工作。ISO在电工技术标准化的所有事项中都与国际电T委员会(IEC)有密切的合作国际标准是根据 ISO/IEC法规、第2部分屮给出的法规进行起草的。技术委员会的主要工作为制定国际标准。经过技术委员公通过的国际标准草案都会分发给各成员团体进行投票。国际标准需要经过至少75%的各成员机构的投票审批之后才能够出版发行。文件中的一些元素可能会是属于某项专利,这一点需要引起注意。ISO没有鉴别这些专利的义务。ISO11898-3是山 ISO/TC22,道路车辆,SC3小组委员会,电器及电子设备技术委员会起草的取消第一版的ISO11898-3,并使用在技术上口经经过修订的ISO11519-2:1994将其替代ISO118%8包含以下的部分,在道路车辆的总标题之下一控制器区域网络CAN部分1:数据伡层和物理信号。部分2:高速媒体访问单元一部分3:低速,容错,媒体专川接口。一部分4:通信的时间触发部分5:低功耗模式下的高速媒体访问单元介绍ISO11898第一次发表是在1993年11月,包括控制器局域网(CAN)数据链层以及高速物理层。在对IsO11898审查和调整中:IsO11898-1描述了数据链层的协议以及媒体访问的控制ISO11898-2对高速的媒体访问单元(MAU)以及媒体专用接口(MDI)进行了规定取消ISO11898-1:2003以及ISO11898-2:2003,取代ISO11898:1993。除了高速CAN之外,最初由ISO115192所包含的低速CAN的发展,获得了诸如容错技术的新的方式。ISO11898部分的主题为对获得此窄错技术的必要条件以及容错本身的规范进行定义和描述。特別是对媒体专用接口和媒体访问控制的部分进行描述。道路车辆-控制器区域网络(CAN)部分3:低速,容错,媒体专用接口1范围此IsSO11898部分制定了在之间安装有控制器区域网终(CAN)的道路车辆的电子控制单元在40 kBit/s到125 kBit/s的传输率之间建立一个交换数字信息的特性。CAN是一个支持分布式控制和多路控制的串行逦信协议。此ISO11898部分介绍了低速CAN应用中的容错方式,以及符合 ISO/OSⅠ分层模型的物理层部分。此ISO11898部分包含以下的物理层部分:一媒体相关接口(MDⅠ)—物理媒体链接(PMA)。另外,此ISO11898部分也对物坦层部分的信号(PLS)以及媒体部分的接入控制(MAC)的定义有一定的影响。在OSI模型中的所有的其他层,既不在CAN协议之内与之匹配以及也不作为用户电平的一部分,也不会影响低速CAN物理层的容错行为,因此不能够构成此ISO11898的一部分。2术语和定义出于使用此文档的目的,使用下列术语和定义。2.1总线所有的儿点都达到了被动链接的允许在两个方向传输的通信网终的布局结构2.2总线故障由诸如屮断,短路等所引起的一个物理总线机能失常的故障。2.3总线值两个互补的逻辑值的其中的显性和隐性。注释:显性值代表一个逻辑“0”隐性值代表一个逻辑“1”。在显性和隐性位同时传输时,所导致的总线值应该为显性。2.4总线电压相对于地面的每个CAN节点的总线电路CANL和CANH的电压。注释: VCAN L和VcANⅡ表示总线电压。差分电压diffCANH和CANL线之间所能看到的电压。注释:Vd=VCAN IIVCAN L2.无故障通信不丢失信息的操作模式。2.7谷错在指定的至少有一个性能下降的总线故障条件下运行的能力。例如:减少信号的信噪比2.8收发器的循环时间延迟从施加一个逻辑信号到收发器逻辑一侧的输入口到收发器逻辑一侧的输出口检测到此信号的延时时间。2低功耗模式降低功耗的工作模式。注释:低功耗模式下不干扰其他节点之间的通信2.10节点链接到通信线路,能够根据给定的通信协议规范通过网终进行父换的组装点。2.11普通模式在网终通信中积极参与(发送和/或接收)的收发器的工作模式2.12T作电容有一个或多个节点能够检测到链接器的总线线路的总电容,受媒体的布局结构和物理介质的影响13物理层实现ECU与总线之间进行连接的电路。2.14物理介质(总线的)成对的电线,平行或双绞线,屏蔽或非屏蔽注释:单个电线,可表示为CANH和CANL。2.15接收器用其将信息转换成逻辑信息或数据信号的物理信号的转换设备2.16发射器将逻辑信息或数据信号转换为电信号,使这些信号能够通过被物理介质进行传输的设备2.17收发器适用于物理层的逻辑信号设各,反之亦然。3缩略语ACK应答CAN控制器区域网终RC循环冗余校验CSMA载波侦听多路访问DC数据长度码ECU电子控制单元EOF结束帧FCE故障本质的界定IC集成电路LAN局域网LLC逻辑链路控制LME层管理实体LPDU LLO协议数据单元SB最低有效位LSDU LLO服务数据单元LS-MAU低速媒体访问单元MAC媒体访问控制MAU媒体访问单元MDI媒体独立接口MPDU MAC协议数据单元MSB最高有效位MSDU MAC服务数据单元NRZ不会返回到零OSI开放式链接系统PL物理层PLS物理层信号PMA物埋介质附属物RTR远程传输请求SOF帧头4OSI参考模型根据在图1中所显示的OSI参考模型,CAN架构代表两层:一数据链路层;物理层。此部分对一个具有容错的低速的CAN收发器的物理层的进行了介绍。只给出了些对数据链层的影响。0SI参考模CAN架构层绍蚊据链层LLCMAC数据链物理物理层MAMDI图1OSl参考模型CAN分层架构5MD规范5.1物理媒休51.1一般说明用来对CAN散播进行传输的物理介质应为一对并行(或双绞线)的线,屏蔽或非屏蔽取决于EMC的要求。分别对线进行标记为CANH和CANL。在显性状态,CANL的电平低于隐性状态时的电平,CANH电平高于隐性状态时的电平。5.1.2总线连接节点CANH和CANL两线的终止端为一个能够被各自的节点识别的终端网络。每条线的总终端电阻应高于或等于1009。但是,由于电阻制造商的限制,指定节点的终端的电阻值不应该低于5009。代表隐性状态的CANL连接到Vc,CANI连接到CANI。图2显示了一个指定总线节点的通用连接法。RTLCAN LCAN HRIH题解a可选图2-个单一总线节点的连接在图2中,终端电阻可选。这意味着,如果适当的满足整体终端的要求,在特定的条件下并不是所有的节点都需要一个独立的终端。51.3工作电容下列规程适用于一个一般用于汽车应用的简单的连线方式。他由一对如在5.1.4中描述的布局式连接的双绞铜线构成。下列在图3和4中所示的基木模型可用于计算ROP题角a驱动器。b连线图3-总线替代电路2C.12CAN H○cANL题解:a对称轴b地线图4参考网络长度1的工作电容使用公式1来对操作电容进行计算CoP=I(C+2C12)+ n Cnode +k Cplug这里CoP工作电容;C线与地线之间的电容参照电线长度单位为米(m)C12两线(假设为对称的)之间的电容参照电线长度单位为米(m)Cmod来自总线侧的一个附加总线节点的电谷;pug一个连接插头的电容;1整个网络电缆长度;n节点的数量k插头数量例子:参考关于下述示范网络的总网络电缆长度的一个典型的操作电容的值,可有下式得出(C+2C12)=120[pF/m514介质时序所允许的最大工作电谷受到诸如下列网络固有参数的限制:一总终端电阻 rterm;布线类型和布局一通信速率一采样点的电压阀值;接地漂移,等等下面的公式提供了个计算最大允许工作电容的计算方法:
- 2020-11-28下载
- 积分:1
-
基于训练序列的信道估计研究
道估计是指描述物理信道对输入信号影响而进行研究的过程,其目的在于识别每组发送天线与接收天线之间的信道冲激响应。本文主要研究了基于训练序列的信道估计, 首先阐述了无线信道中信号的传播方式、信号的损失以及衰落效应、多径效应、时变效应等特性。接着在介绍信道特性的基础上着重介绍了比较经典的时域和频域信道估计方法,并从时域的角度介绍了最小二乘算法。最后对基于训练序列的信道估计进行仿真实验,比较均方误差大小,给出仿真曲线和结果分析。
- 2021-05-07下载
- 积分:1
-
UWB定位DW1000官方手册中文翻译文档
uwb定位英文版看起来很吃力,用翻译狗翻译的官方dw1000芯片通用参考手册,给大家提供中文手册技术参考。
- 2020-12-05下载
- 积分:1